3M™ Harvest RC is the next generation in harvest and clarification technology for high cell density cultures.

  • Industries : Biopharmaceutical manufacturing
  • OverallDiameterMetric : 7.7 cm
  • Net Weight (Metric) : 75.8 g
  • Micron Rating : 0.2 μm
  • Flow Rate (Metric) : 4.2 ml/min
  • categoryName : Chromatography Filters
  • Flow Rate (Imperial) : 0.001 gal/min
  • OverallHeightImperial : 3.39 in
  • Overall Diameter (Imperial) : 3.03 in
  • OverallHeightMetric : 8.6 cm
  • End Modification : 3/4 in Sanitary
  • Filter Type : Single Use
  • ProductSeries : Harvest RC
  • FilterTechnology : Anion exchange chromatography
  • Application : Harvest And Clarification

Product details

This solution is designed as an efficient option to increase monoclonal antibody (mAb) yields while simplifying the upstream process by replacing the centrifuge and/or depth filtration unit operations.
  • Simplification of high cell density cell culture fluid clarification unit operations.
  • Remove cells, cell debris and DNA (<500 ppb) from the harvested cell culture fluid.
  • Optimised for PCV high density CHO cell culture (5-8% PCV)
  • Replacement of primary, secondary and guard membrane clarification stages.
  • Typical product recovery of 95+% (capsules)
  • Synthetic chromatographic harvest media with chemically defined extractables.
  • Predictable scaling from discovery to manufacturing.
  • Lower total cost of manufacturing compared to centrifugation and depth filtration.
  • Lower consumption of buffer and water compared to depth filtration.
  • Capsules fit into laboratory to manufacturing scale workflows.

Suggested Applications

  • Clarification for CHO harvest cell culture fluid
  • Single-stage chromatographic clarification
  • Single-stage chromatographic clarification

Product specifications

Industries
Industries

Biopharmaceutical manufacturing

OverallDiameterMetric
OverallDiameterMetric

7.7 cm

Net Weight (Metric)
Net Weight (Metric)

75.8 g

Micron Rating
Micron Rating

0.2 μm

Flow Rate (Metric)
Flow Rate (Metric)

4.2 ml/min

categoryName
categoryName

Chromatography Filters

Flow Rate (Imperial)
Flow Rate (Imperial)

0.001 gal/min

OverallHeightImperial
OverallHeightImperial

3.39 in

Overall Diameter (Imperial)
Overall Diameter (Imperial)

3.03 in

OverallHeightMetric
OverallHeightMetric

8.6 cm

End Modification
End Modification

3/4 in Sanitary

Filter Type
Filter Type

Single Use

ProductSeries
ProductSeries

Harvest RC

FilterTechnology
FilterTechnology

Anion exchange chromatography

Application
Application

Harvest And Clarification

Ask an expert