Skip to main content

"We've detected that you're visiting from {0}. Would you like to switch languages for tailored content?"

3M™ Harvest RC, BC25, Sanitary, EMP303HRC2FA, 2/Case

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

3M™ Harvest RC, BC25, Sanitary, EMP303HRC2FA, 2/Case
3M(TM) Harvest RC family
3M(TM) Harvest RC family
3M™ Harvest RC family
3M(TM) Harvest RC family
Harvest RC BC25 Sanitary

About the product

3M™ Harvest RC is the next generation in harvest and clarification technology for high cell density cultures.

  • Industries : Biopharmaceutical manufacturing
  • OverallDiameterMetric : 7.7 cm
  • Filter Technology : Anion exchange chromatography
  • Micron Rating : 0.2 μm
  • OverallDiameterImperial : 3.03 in
  • Flow Rate (Metric) : 4.2 ml/min
  • EndModification : 3/4 in Sanitary
  • categoryName : Chromatography Filters
  • Overall Height (Imperial) : 3.39 in
  • FilterType : Single Use
  • OverallHeightMetric : 8.6 cm
  • FlowRateImperial : 0.001 gal/min
  • NetWeightMetric : 75.8 g
  • ProductSeries : Harvest RC
  • Application : Harvest And Clarification

Product details

This solution is designed as an efficient option to increase monoclonal antibody (mAb) yields while simplifying the upstream process by replacing the centrifuge and/or depth filtration unit operations.
  • Simplification of high cell density cell culture fluid clarification unit operations.
  • Remove cells, cell debris and DNA (<500 ppb) from the harvested cell culture fluid.
  • Optimised for PCV high density CHO cell culture (5-8% PCV)
  • Replacement of primary, secondary and guard membrane clarification stages.
  • Typical product recovery of 95+% (capsules)
  • Synthetic chromatographic harvest media with chemically defined extractables.
  • Predictable scaling from discovery to manufacturing.
  • Lower total cost of manufacturing compared to centrifugation and depth filtration.
  • Lower consumption of buffer and water compared to depth filtration.
  • Capsules fit into laboratory to manufacturing scale workflows.

Suggested Applications

  • Clarification for CHO harvest cell culture fluid
  • Single-stage chromatographic clarification
  • Single-stage chromatographic clarification

Product specifications

Industries
Industries

Biopharmaceutical manufacturing

OverallDiameterMetric
OverallDiameterMetric

7.7 cm

Filter Technology
Filter Technology

Anion exchange chromatography

Micron Rating
Micron Rating

0.2 μm

OverallDiameterImperial
OverallDiameterImperial

3.03 in

Flow Rate (Metric)
Flow Rate (Metric)

4.2 ml/min

EndModification
EndModification

3/4 in Sanitary

categoryName
categoryName

Chromatography Filters

Overall Height (Imperial)
Overall Height (Imperial)

3.39 in

FilterType
FilterType

Single Use

OverallHeightMetric
OverallHeightMetric

8.6 cm

FlowRateImperial
FlowRateImperial

0.001 gal/min

NetWeightMetric
NetWeightMetric

75.8 g

ProductSeries
ProductSeries

Harvest RC

Application
Application

Harvest And Clarification