Skip to main content

We've detected that you're visiting from United States of America. Would you like to switch languages for tailored content?

  1. 3M™ Harvest RC

3M™ Harvest RC, BC25, Sanitary, EMP303HRC2FA, 2/Case

undefined

Hover over image to zoom

  • 2/5
  • 3/5
  • 4/5
  • 5/5
3M™ Harvest RC, BC25, Sanitary, EMP303HRC2FA, 2/Case
3M(TM) Harvest RC family
3M(TM) Harvest RC family
3M™ Harvest RC family

About the product

3M™ Harvest RC is the next generation in harvest and clarification technology for high cell density cultures.

  • Industries : Biopharmaceutical manufacturing
  • OverallDiameterMetric : 7.7 cm
  • Filter Technology : Anion exchange chromatography
  • Micron Rating : 0.2 μm
  • Flow Rate (Metric) : 4.2 ml/min
  • EndModification : 3/4" Sanitary
  • OverallHeightImperial : 3.39 in
  • Overall Diameter (Imperial) : 3.03 in
  • FlowRateImperial : 0.001 gal/min
  • NetWeightMetric : 75.8 g
  • Category name : Chromatography Filters
  • Filter Type : Single Use
  • ProductSeries : Harvest RC
  • Application : Harvest and clarification
  • Overall Height (Metric) : 8.6 cm

Product details

This solution is designed as an efficient option to increase monoclonal antibody (mAb) yields while simplifying the upstream process by replacing the centrifuge and/or depth filtration unit operations.
  • Single-stage, single-use chromatographic clarification solution.
  • Replaces primary, secondary, and guard membrane clarification stages.
  • Remove cells, cell debris and DNA (<500 ppb) from the harvested cell culture fluid.
  • High mAb product recovery (90-95%).
  • Predictably scales from laboratory to manufacturing.
  • Turbidity of 3M™ Harvest RC clarified cell culture fluid <15 NTU

Suggested Applications

  • Clarification for CHO harvest cell culture fluid
  • Single-stage chromatographic clarification
  • Single-stage chromatographic clarification

Product specifications

Industries
Industries

Biopharmaceutical manufacturing

OverallDiameterMetric
OverallDiameterMetric

7.7 cm

Filter Technology
Filter Technology

Anion exchange chromatography

Micron Rating
Micron Rating

0.2 μm

Flow Rate (Metric)
Flow Rate (Metric)

4.2 ml/min

EndModification
EndModification

3/4" Sanitary

OverallHeightImperial
OverallHeightImperial

3.39 in

Overall Diameter (Imperial)
Overall Diameter (Imperial)

3.03 in

FlowRateImperial
FlowRateImperial

0.001 gal/min

NetWeightMetric
NetWeightMetric

75.8 g

Category name
Category name

Chromatography Filters

Filter Type
Filter Type

Single Use

ProductSeries
ProductSeries

Harvest RC

Application
Application

Harvest and clarification

Overall Height (Metric)
Overall Height (Metric)

8.6 cm

Ask an expert

Thank You Message

Thank you!

Your form was submitted successfully! 

Abstract rendering showing four layers of green curl patterns covering the frame.