Skip to main content

"We've detected that you're visiting from {0}. Would you like to switch languages for tailored content?"

3M™ Liqui-Cel™ MM Series Membrane Contactor

1 Products available

Hover over image to zoom

3M™ Liqui-Cel™ MM Series Membrane Contactor

About the product

The 3M™ Liqui-Cel™ MM Series Membrane Contactor is our smallest degassing (debubbling) devices. These devices pack a high membrane surface area into a very small footprint. Used primarily in laboratory and analytical applications, degassing with these small point of use degassers/debubblers may help (a) improve measurement reliability, (b) reduce rework and (c) improve product quality.

Product options

1-1 of 1 Products

Select Filters to narrow your product list

Product name and IDs 3M ID OverallLengthImperial Overall Length (Metric) Overall Diameter (Imperial) Overall Diameter (Metric) Product Type Filter Technology Industries Product Series Brand

3M ID

7010439959

OverallLengthImperial

5.51 in

Overall Length (Metric)

140 mm

Overall Diameter (Imperial)

1.69 in

Overall Diameter (Metric)

43 mm

Product Type

Membrane Contactor

Filter Technology

Membrane

Industries

Manufacturing

Product Series

MM

Brand

Liqui-Cel™

Product details

Lab-scale systems producing deionized (DI) water have limited space to incorporate degassing technology. The compact design of the Liqui-Cel MM series allows manufacturers of DI water systems to provide degassed DI water without taking up a lot of space inside the system. Products are available to handle flow rates from 5 ml/min to 3000 ml/min.

About 3M™ Liqui-Cel™ Membrane Contactors

3M™ Liqui-Cel™ Membrane Contactors provide efficient dissolved gas control in a compact design. Capable of adding gases to or removing dissolved gases from compatible liquid streams, these gas transfer devices utilize hollow fibre membrane technology that may help facilities around the world improve operating efficiency, performance and protect product quality.

The presence of dissolved gases, such as oxygen, carbon dioxide, nitrogen and other non-condensable gases can cause a number of difficulties. Process interruptions, yield loss, corrosion, surface defects, unreliable measurement readings, poor product quality, higher operating costs and equipment inefficiency are a few examples of challenges faced by various industries when dissolved gases and air bubbles are not consistently controlled.

The 3M™ Liqui-Cel™ Membrane Contactor product offering includes products made with various materials of construction and a wide-range of flow capacities to meet process and application requirements. Their modular nature makes them easy to incorporate into systems with lower weight and less space than other conventional technologies, such as vacuum towers or forced draft deaerators. 3M™ Liqui-Cel™ Membrane Contactors do not require chemicals in operation and can be an effective alternative to chemical treatment options, such as oxygen scavengers in boiler feedwater or caustic/acid in reverse osmosis (RO) and other deionization systems. This may be particularly advantageous for facilities that want to reduce on-site chemical use as part of their sustainability goals.

How 3M™ Liqui-Cel™ Membrane Contactors Membrane Contactors Work

3M™ Liqui-Cel™ Membrane Contactors utilize microporous or non-porous, semi permeable hollow fibre membrane that is placed inside a contactor housing. In our EXF, SP, and MM-0.5x1 and MM-0.75x1 series membrane contactors, liquid flows around the outside of the hollow fibre membrane while a vacuum and/or sweep gas is applied to the inside of the hollow fibre during operation. In our other MM series membrane contactors liquid and gas flows are opposite: liquid flows inside of the hollow fibre membrane while a vacuum and/or sweep gas is applied to the outside of the hollow fibre.

  • Compact design for tight space requirements
  • Ideal for proof-of concept testing
  • Suitable for low flow rate and lab-scale applications
  • Utilizes microporous hollow fibre membrane, similar to the EXF series, but devices have either transverse liquid flow outside of the fibres or parallel flow designs where liquid flows on the inside of the hollow fibre

Suggested Applications

  • Debubbling water in benchtop pure water systems
  • Degassing sample water used in laboratory analysers
  • Debubbling water in analytical and diagnostic systems to help reduce inaccurate measurements and readings

Product specifications

Industries
Industries

Manufacturing

Brand
Brand

Liqui-Cel™

Overall Length (Imperial)
Overall Length (Imperial)

5.51 in

Overall Diameter (Imperial)
Overall Diameter (Imperial)

1.69 in

Overall Length (Metric)
Overall Length (Metric)

140 mm

Category Name
Category Name

Degassing Membrane Contactors

Product Type
Product Type

Membrane Contactor

Filter Technology
Filter Technology

Membrane

Overall Diameter (Metric)
Overall Diameter (Metric)

43 mm

Product Series
Product Series

MM