Passa al contenuto principale

Abbiamo rilevato che stai visitando il nostro sito da Stati Uniti d'America. Vuoi cambiare lingua per vedere contenuti personalizzati?

3M™ LifeASSURE™ PDA Series Filter Cartridge

4 Prodotti disponibili

undefined

Passa il mouse sull'immagine per ingrandire

3M™ LifeASSURE™ PDA Series Filter Cartridge

Informazioni sul prodotto

3M™ LifeASSURE™ PDA Series Filter Cartridges combine two asymmetric polyethersulfone (PES) membrane layers with Advanced Pleat Technology. Our filters have applications in sterilising filtration of biological solutions where low protein binding is critical.

Opzioni prodotto

1-4 di 4 Prodotti

Seleziona Filtri per restringere la lista dei prodotti

Dettagli del prodotto

Get high throughput and fast flow with 3M™ LifeASSURE™ PDA Series Filter Cartridges. Incorporating two layers of polyethersulfone (PES) membrane, the highly asymmetric upstream layer provides prefiltration capacity for the downstream layer, which is also asymmetric. Together, the membrane layers create a gradient membrane pore morphology that provides relatively high contaminant capacity and fast flow rates in a sterilising grade membrane filter. 3M LifeASSURE PDA Series filter Cartridges also feature our innovative Advanced Pleat Technology construction that helps extend service life. This design technology is intended to increase the useful surface area while maintaining open flow paths between media pleats. We manufacture LifeASSURE PDA Series filter cartridges using all-polypropylene structural components (end caps, adapters, media support, inner core and outer cage). We offer LifeASSURE PDA filter cartridges in multiple lengths to match the dimension and sealing requirements for most cartridge housings currently available. Engineered for Quality and Reliability Our Quality Management System is approved by an accredited registering body to the ISO 9001:2008 and ISO 13485:2003 Quality Management Systems, and the cartridges are 100% forward flow integrity tested prior to shipment. We ship all LifeASSURE PDA cartridge and capsule filters with a Certificate of Quality affirming compliance with manufacturing quality specifications. Additionally, supporting Drug Master File (DMF) documentation is on file with the United States Food and Drug Administration (FDA) and a complete LifeASSURE PDA Validation Guide is available upon request. Meeting Your Scale-Up Needs 3M are pleased to offer a full range of LifeASSURE PDA sterilising-grade filters to meet your scale-up process needs. This includes pre-sterilised or sterilisable disposable capsules in various sizes as well as full-size cartridges. We also offer filter discs when even smaller membrane surface areas are required.
  • Highly asymmetric dual zone 0.2 or 0.1 micron rated PES membrane provides reliable sterilising filtration.
  • Excellent contaminant capacity, flow rates, and life resulting from robust double-asymmetric membrane layer filter construction.
  • Hydrophilic asymmetric polyethersulfone membrane enables wet out in aqueous solutions for integrity testing.
  • 100% forward flow integrity tested prior to release.
  • Fully supported by Validation Guide and DMF.
  • Use to meet 0.2 and 0.1 μm rated filtration requirements for critical sterilisation applications of biological solutions.
  • 21 CFR compliant materials of construction and other documentation supports validation and regulatory submissions.

Applicazioni suggerite

  • Use to meet 0.2 and 0.1 μm rated filtration requirements for critical sterilisation applications of biological solutions

Specifiche del prodotto

Lunghezza complessiva (misure imperiali)
Lunghezza complessiva (misure imperiali)

30 in, 20 in, 10 in

Industries
Industries

Produzione biofarmaceutica

Fine modifica
Fine modifica

226 O-ring & Spear

Applicazioni
Applicazioni

Filtrazione sterile

OverallLengthImperial
OverallLengthImperial

20 in

Nome categoria
Nome categoria

Cartucce a membrana pieghettate

Serie prodotto
Serie prodotto

PDA

ProductForm
ProductForm

Cartuccia

Diametro (unità misura Imperiale anglosassone)
Diametro (unità misura Imperiale anglosassone)

2.76 in

Tipo di filtro
Tipo di filtro

Surface

categoryName
categoryName

Cartucce a membrana pieghettate

Classificazione Micron (assoluta)
Classificazione Micron (assoluta)

0.2 absolute, @ 99.9%

Tecnologia di filtraggio
Tecnologia di filtraggio

Membrana

Trademark2
Trademark2

LifeASSURE™

Stato del prodotto
Stato del prodotto

Cartuccia

Settori
Settori

Produzione biofarmaceutica

Grade
Grade

PDA020

EndModification
EndModification

226 O-ring & Spear

Tipo di prodotto
Tipo di prodotto

Membrana plissettata

FilterType
FilterType

Surface

Marchio
Marchio

LifeASSURE™

Grana
Grana

PDA020

Lunghezza complessiva (misure metriche)
Lunghezza complessiva (misure metriche)

76.2 cm, 50.8 cm, 25.4 cm

FilterTechnology
FilterTechnology

Membrana

Application
Application

Filtrazione sterile

Diametro complessivo (misure metriche)
Diametro complessivo (misure metriche)

7 cm

Chiedi a un esperto

Informazioni tecnico-scientifiche rivolte ai professionisti sanitari.

Dispositivi medici marcati CE.

Vuoi procedere?