Skip to main content

"We've detected that you're visiting from {0}. Would you like to switch languages for tailored content?"

3M™ Attest™ Super Rapid Steam Biological Indicator Challenge Pack withType 5 CI, 41482V, Brown Cap, 24 min, 24/CS

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

3M™ Attest™ Super Rapid Steam Biological Indicator Challenge Pack withType 5 CI, 41482V, Brown Cap, 24 min, 24/CS
3M™ Attest™ Super Rapid 5 Steam-Plus Challenge Pack 41482V
(1) BI results in just 24 minutes
(2) FDA-cleared pack and ISO-compliant components
(3) Monitors 270F/132C - 275F/135C dynamic-air-removal steam sterilization cycles
(4) For use with 3M Attest Auto-readers 490 & 490M

About the product

The 3M™ Attest™ Super Rapid Readout Steam Biological Indicator Challenge Pack with Type 5 CI 41482*/4182V/4182VF, is a pre-assembled, white-wrapped test pack designed to monitor 270°F/132°C to 275°F/135°C dynamic-air-removal saturated steam sterilisation cycles. Each pack includes a 3M™ Attest™ Steam Chemical Integrator, Type 5, and a 3M™ Attest™ Super Rapid Readout Steam Biological Indicator, 1492V, brown cap, 24 minute.

  • Trademark2 : Attest™
  • IncubationPeriod : 24 min
  • categoryName : Biological Indicators
  • CapColor : Brown

Product details

The 3M™ Attest™ Super Rapid Readout Steam Biological Indicator Challenge Pack with Type 5 CI 41482*/4182V/4182VF comes pre-assembled in a white wrap and includes a 3M™ Attest™ Chemical Integrator, Type 5, one 3M™ Attest™ Super Rapid Biological Indicator 1492V, 24 minute, a record-keeping sheet and a chemical process indicator on the pack label for convenience and ease of use. The biological indicator (BI) and chemical integrator (CI) included are ISO-compliant. The BI must be used with the 3M™ Attest™ Auto-reader 490 or 490M.

This convenient, disposable challenge pack is specifically designed for rapid and reliable qualification testing and routine monitoring of 270°F/132°C to 275°F/135°C dynamic‑air‑removal (pre‑vacuum and steam‑flush pressure‑pulse (SFPP)) saturated steam sterilisation cycles in healthcare facilities. The pack presents a challenge to the sterilisation process equivalent to the user-assembled biological indicator (BI) challenge test pack (16-towel PCD) recommended by the Association for the Advancement of Medical Instrumentation (AAMI).

* where available

  • Pre-assembled, easy-to-use steam challenge pack includes a 3M™ Attest™ Steam Chemical Integrator, Type 5, and a 3M™ Attest™ Super Rapid Readout Steam Biological Indicator 1492V, Brown Cap, 24 minute
  • BI results in just 24 minutes
  • Monitors 270°F/132°C to 275°F/135°C dynamic-air-removal steam sterilisation cycles
  • Presents a challenge to the steam sterilisation process equivalent to the user-assembled BI challenge test pack (16-towel PCD) recommended by AAMI
  • ISO-compliant components
  • UDI-compliant 2-D barcode technology to capture BI GTIN, use-by date and lot code with handheld scanner
  • BI compatible with the 3M™ Attest™ Auto-reader 490 or 490M

Product specifications

Trademark2
Trademark2

Attest™

IncubationPeriod
IncubationPeriod

24 min

categoryName
categoryName

Biological Indicators

CapColor
CapColor

Brown

Contact a Solventum representative

There was an error processing your request. Please try again later.