Pressure Equipment Directive 2014/68/EU:
3M High Flow housings are fully compliant with and built to PED 2014/68/EU Article 4.3 “Sound Engineering Practice” as standard.
ATEX Directive 2014/34/EU
The 3M High Flow Coreline housings are ATEX approved as standard for use in ATEX condition II 2 GD c IIC/IIIC.
Marking and documentation
The housings are clearly marked and delivered with a EN10204 Certificate of Conformity 2.2. The user of these housings must ensure that they are used in compliance with the requirements of these PED and ATEX directives at all times, and in accordance with the instruction manual supplied.
Food Contact Directive (EC) 1935/2004
The housings are constructed from 316 and 316L stainless steel (wetted parts in contact) and delivered with O-rings that are compliant to FDA (there are no other non-316 parts in contact).
Design
In addition to the standard Coreline housing range described here, 3M High Flow System Housings can be built upon request to a wide range of specifications and design and construction standards. These routinely include PED Category IV and for use with Hazardous (Group 1) liquids and Gas/Vapour. Design and constructions codes can include (but are not limited to) EN13445, AD Merkblatter, ASME Div VIII & U Stamp and CODAP. Materials can include in addition to 316 (but not limited to) 304 and Uranus B6 Super Duplex steels
•3M High Flow Series Filter Housings are 33% to 50% smaller than competitively sized housings for a given flow rate
•Single Cartridge Housings available for 10 in, 40 in and 60 in High Flow Cartridges
•Robust cartridge centre-post design - Eliminates bulky support plates providing easy access to housing internals
•Hinged cover for easy filter cartridge change-outs.
•ASME Code design meets high quality and performance standards.