Skip to main content

"We've detected that you're visiting from {0}. Would you like to switch languages for tailored content?"

3M™ Harvest RC, WP6, EMP006HRC2FA, 4/Case

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

Hover over image to zoom

3M™ Harvest RC, WP6, EMP006HRC2FA, 4/Case
3M™ Harvest RC family with 3M™ Harvest RC Chromatographic Clarifier BT500
3M Harvest RC, WP6
3M(TM) Harvest RC, WP6
3M(TM) Harvest RC, WP6
Harvest RC WP6 wbox
Harvest RC WP6 wgloves
Harvest RC WP6

About the product

3M™ Harvest RC is the next generation in harvest and clarification technology for high cell density cultures.

  • Industries : Biopharmaceutical manufacturing
  • MicronRating : 0.2 μm
  • categoryName : Chromatography Filters
  • Overall Height (Imperial) : 3.46 in
  • FilterType : Single Use
  • OverallLengthMetric : 12.8 cm
  • Overall Length (Imperial) : 5.04 in
  • Overall Width (Metric) : 8.5 cm
  • ProductSeries : Harvest RC
  • Overall Width (Imperial) : 3.35 in
  • FilterTechnology : Anion exchange chromatography
  • Application : Harvest And Clarification
  • Overall Height (Metric) : 8.8 cm

Product details

This solution is designed as an efficient option to increase monoclonal antibody (mAb) yields while simplifying the upstream process by replacing the centrifuge and/or depth filtration unit operations.
  • Simplification of high cell density cell culture fluid clarification unit operations.
  • Remove cells, cell debris and DNA (<500 ppb) from the harvested cell culture fluid.
  • Optimised for PCV high density CHO cell culture (5-8% PCV)
  • Replacement of primary, secondary and guard membrane clarification stages.
  • Typical product recovery of 95+% (capsules)
  • Synthetic chromatographic harvest media with chemically defined extractables.
  • Predictable scaling from discovery to manufacturing.
  • Lower total cost of manufacturing compared to centrifugation and depth filtration.
  • Lower consumption of buffer and water compared to depth filtration.
  • Capsules fit into laboratory to manufacturing scale workflows.

Suggested Applications

  • Clarification for CHO harvest cell culture fluid
  • Single-stage chromatographic clarification
  • Single-stage chromatographic clarification

Product specifications

Industries
Industries

Biopharmaceutical manufacturing

MicronRating
MicronRating

0.2 μm

categoryName
categoryName

Chromatography Filters

Overall Height (Imperial)
Overall Height (Imperial)

3.46 in

FilterType
FilterType

Single Use

OverallLengthMetric
OverallLengthMetric

12.8 cm

Overall Length (Imperial)
Overall Length (Imperial)

5.04 in

Overall Width (Metric)
Overall Width (Metric)

8.5 cm

ProductSeries
ProductSeries

Harvest RC

Overall Width (Imperial)
Overall Width (Imperial)

3.35 in

FilterTechnology
FilterTechnology

Anion exchange chromatography

Application
Application

Harvest And Clarification

Overall Height (Metric)
Overall Height (Metric)

8.8 cm

Ask an expert

Thank You Message

Thank you!

Your form was submitted successfully! 

Abstract rendering showing four layers of green curl patterns covering the frame.